Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Abstract
Brief Report
Case Report
Case Report and Review
Case Series
Commentary
Editorial
Erratum
How do I do it
How I do it?
Invited Editorial
Letter to Editor
Letter to the Editor
Letters to Editor
Letters to the Editor
Mini Review
Original Article
Original Articles
Others
Review Article
Short communication
Short Paper
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Abstract
Brief Report
Case Report
Case Report and Review
Case Series
Commentary
Editorial
Erratum
How do I do it
How I do it?
Invited Editorial
Letter to Editor
Letter to the Editor
Letters to Editor
Letters to the Editor
Mini Review
Original Article
Original Articles
Others
Review Article
Short communication
Short Paper
View/Download PDF

Translate this page into:

Letters to Editor
6 (
1
); 65-66
doi:
10.4103/0974-2727.129100

Accurate Laboratory Detection of Oxacillin Resistance in Staphylococcus aureus: Challenges and Pitfalls

Department of Pathology, Division of Microbiology, Santa Casa School of Medicine, São Paulo, Brazil
Department of Pediatrics, Division of Pediatric Infectious Diseases, Santa Casa School of Medicine, São Paulo, Brazil

Address for correspondence: Dr. Marcelo J Mimica, E-mail: mjmimica@hotmail.com

Licence

This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Disclaimer:
This article was originally published by Medknow Publications & Media Pvt Ltd and was migrated to Scientific Scholar after the change of Publisher.

Sir,

Staphylococcus aureus is a major pathogen linked to both nosocomial and community-associated infections. New community-associated methicillin resistant clones and decreased levels of susceptibility to vancomycin are more recent problems.[1] In this setting, accurate laboratory detection of oxacillin resistance is paramount to ensure appropriate clinical and epidemiological decisions.[23] Although there are recommendations from both the Clinical and Laboratory Standards Institute (CLSI) and the European Committee on Antimicrobial Susceptibility Testing (EUCAST), there is also, still, discussion regarding the method of election for routine use by clinical microbiology laboratories.

Pillai et al.[4] reported recently in this journal their study addressing this subject, and found suboptimal accuracies for the evaluated phenotypic methods (oxacillin disk diffusion test and oxacillin agar screen test). CLSI and EUCAST include the cefoxitin disk diffusion test in their recommendations for detection of beta-lactam resistance, but Pillai et al. did not evaluate specifically this method. We have previously studied[23] the accuracy of both oxacillin and cefoxitin disk diffusion tests, oxacillin agar screening plate and Etest™ using the presence of the mecA gene as gold standard, and concluded that, even with the cefoxitin modified breakpoints that were later adopted, there are still major errors with the disk diffusion tests. Etest™ and oxacillin agar plate showed higher accuracy.

Other studies in addition to Pillai's and ours have shown the limitations of relying only on phenotypic tests and some have even advocated the use of molecular methods for all isolates from sterile body fluids. However, another option, in our opinion, since molecular detection is not readily available in most clinical laboratories throughout the world, would be increase the sensitivity (usually with not very significant decrease on specificity) on testing such clinically important isolates by using two methods (example: Oxacillin and cefoxitin disk tests or oxacillin screening plate and cefoxitin disk test) concomitantly.

REFERENCES

  1. , , , . Healthcare associated PVL negative methicillin-resistant Staphylococcus aureus with SCCmec type IV. Pediatr Infect Dis J. 2009;28:934.
    [Google Scholar]
  2. , , , , , , . Detection of methicillin resistance in Staphylococcus aureus isolated from pediatric patients: Is the cefoxitin disk diffusion test accurate enough? Braz J Infect Dis. 2007;11:415-7.
    [Google Scholar]
  3. , , , , , . Comparison of five methods for oxacillin susceptibility testing of Staphylococcus aureus isolates from cystic fibrosis patients. Rev Inst Med Trop Sao Paulo. 2012;54:305-6.
    [Google Scholar]
  4. , , , . Detection of methicillin resistance in Staphylococcus aureus by polymerase chain reaction and conventional methods: A comparative study. J Lab Physicians. 2012;4:83-8.
    [Google Scholar]

    Fulltext Views
    643

    PDF downloads
    205
    View/Download PDF