Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Abstract
Brief Report
Case Report
Case Report and Review
Case Series
Commentary
Editorial
Erratum
How do I do it
How I do it?
Invited Editorial
Letter to Editor
Letter to the Editor
Letters to Editor
Letters to the Editor
Mini Review
Original Article
Original Articles
Others
Review Article
Short communication
Short Paper
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Abstract
Brief Report
Case Report
Case Report and Review
Case Series
Commentary
Editorial
Erratum
How do I do it
How I do it?
Invited Editorial
Letter to Editor
Letter to the Editor
Letters to Editor
Letters to the Editor
Mini Review
Original Article
Original Articles
Others
Review Article
Short communication
Short Paper
View/Download PDF

Translate this page into:

Letter to the Editor
15 (
3
); 470-471
doi:
10.1055/s-0042-1757420

Cryoglobulinemia Diagnosed by Peripheral Smear Examination: Value of a Basic Underestimated Test

Department of Pathology, PSG Institute of Medical Sciences and Research, Coimbatore, Tamil Nadu, India
Department of Medicine, PSG Institute of Medical Sciences and Research, Coimbatore, Tamil Nadu, India

Address for correspondence: Sakthisankari Shanmugasundaram, MD, Department of Pathology, PSG Institute of Medical Sciences and Research, Peelamedu, Coimbatore, Tamil Nadu, 641004, India (e-mail: sakthissankari@gmail.com).

Licence
This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial-License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon.
Disclaimer:
This article was originally published by Thieme Medical and Scientific Publishers Pvt. Ltd. and was migrated to Scientific Scholar after the change of Publisher.

A 58-year-old female with a history of vasculitis presented to the hospital with sudden onset hemoptysis, ulceration over bilateral lower limbs, and low-grade intermittent fever. Computed tomographic scan of chest revealed pulmonary hemorrhage. Investigations showed a hemoglobin of 5.8 g/dL, pseudoleukocytosis (46 × 103/μL), and platelet count of 483 × 103/μL. Examination of the Leishman-stained peripheral smear showed blue background with grossly visible agglutinates (Fig. 1A) and a normal total white blood cell count. Pseudoleukocytosis could have been the result of counting of precipitated cryoglobulin deposits as leukocytes by the automated cell counter.[1]

(A) Peripheral smear showing a blue background and visible agglutinates. (B) Basophilic amorphous globular deposits in the background. (C) Intracytoplasmic faint basophilic deposits within neutrophils.
Fig. 1
(A) Peripheral smear showing a blue background and visible agglutinates. (B) Basophilic amorphous globular deposits in the background. (C) Intracytoplasmic faint basophilic deposits within neutrophils.

Basophilic to faint eosinophilic amorphous globular and granular deposits in the background (Fig. 1B and inset) and intracytoplasmic vacuoles within the neutrophils (Fig. 1C) were observed suggestive of cryoglobulin precipitates. Qualitative determination of cryoglobulin was positive—cryoglobulin deposits at 4°C (Fig. 2A) and absence of deposits at 37°C (Fig. 2B). Further workup showed elevated serum cryoglobulin (880.8 mg/L), low C3 (109.10 mg/dL), near-normal C4 (3.02 mg/dL), and antineutrophil cytoplasmic antibodies—proteinase 3 positive, supporting the diagnosis. She was negative for hepatitis C virus, hepatitis B virus, and human immunodeficiency virus. Renal function tests revealed elevated urea (112 mg/dL) and creatinine (6.32 mg/dL) levels. The patient improved following treatment with steroids, cyclophosphamide, and plasmapheresis.

(A) Qualitative test for cryoglobulin showing cryoglobulin deposits in the patient's serum at 4°C. (B) Disappearance of the deposits after warming at 37°C.
Fig. 2
(A) Qualitative test for cryoglobulin showing cryoglobulin deposits in the patient's serum at 4°C. (B) Disappearance of the deposits after warming at 37°C.

Cryoglobulin deposits on peripheral smear serving as an initial manifestation of the underlying disease process have been reported previously.[24]

The purpose of this case is to remind the importance of manual screening of peripheral smears in an era of automation. Findings, as observed in our case, can pave the way for early identification and treatment of clinically unsuspected cases.

Informed Consent

Waiver of consent has been obtained.

Ethical Approval

Obtained.

Conflict of Interest

None declared.

References

  1. , , , , . Remarkable pseudoleucocytosis induced by mild cryoglobulinemia. Clin Chem Lab Med. 2020;58(11):e291-e293.
    [CrossRef] [PubMed] [Google Scholar]
  2. . Cryoglobulin deposits on a blood smear. Blood. 2012;120(09):1764. DOI: 10.1182/blood-2012-01-398198
    [CrossRef] [PubMed] [Google Scholar]
  3. , , , . Cryoglobulinemia as an initial manifestation of underlying hematological malignancy: a rare occurrence in India. J Lab Physicians. 2014;6(02):127-129.
    [CrossRef] [PubMed] [Google Scholar]
  4. , , . Cryoglobulin crystals deposited in a peripheral blood film and phagocytosed by neutrophils. Br J Haematol. 2021;195(04):484.
    [CrossRef] [PubMed] [Google Scholar]

Fulltext Views
821

PDF downloads
265
View/Download PDF
Download Citations
BibTeX
RIS
Show Sections